Model | JHY5000 |
Input DC (PV) |
|
Kuasa Input PV Maksimum | 7000W |
Voltan DC Maksimum | 500V |
Voltan Permulaan | 150V |
Voltan Ternilai | 360V |
Julat Voltan Kendalian MPPT | 120V ~430V |
Bilangan MPPT | 2 |
Bilangan Rentetan MPPT Setiap Litar | 1 |
Arus Input Maksimum Setiap MPPT | 15A |
Arus Litar pintas Maksimum Setiap MPPT | 18.9A |
Output AC (Bersambung Grid) |
|
Penilaian | 5000W |
Kuasa Nampak Maksimum | 5500VA |
Voltan Terkadar (Julat) | 230V |
Kekerapan Dinilai (Julat) | 50Hz / 60Hz |
Arus Keluaran Maksimum | 23.9A |
Faktor Kuasa | 0.8 Hadapan ~ 0.8 Belakang |
THDi | < 3% |
Jenis Sambungan Grid | L+N+PE |
Input Bateri |
|
Jenis Bateri | Bateri Litium-Ion / Plumbum-Asid |
Julat Voltan Kendalian | 41.6V ~ 58.5V |
Arus Caj/Penyahcasan Maksimum | 95A / 100A |
Output AC (Sandaran Kuasa) |
|
Kuasa Output Maksimum | 4500W |
Kuasa Nampak Maksimum | 4500VA |
Arus Keluaran Maksimum | 23.9A |
Voltan Ternilai | 230V |
Kekerapan Dinilai | 50Hz / 60Hz |
THDv | < 3% |
Masa Bertukar | < 20ms (Beban Kapasitif); < 10ms (Beban Rintangan) |
Kecekapan |
|
Kecekapan Maksimum | 0.978 |
Kecekapan Eropah | 0.97 |
Kecekapan MPPT | 0.9999 |
Kemudahan Perlindungan |
|
Suis DC | Disokong |
Perlindungan Kilat AC | Disokong |
Perlindungan Litar pintas AC | Disokong |
Pemantauan Kerosakan Tanah | Disokong |
Pemantauan Grid | Disokong |
Perlindungan Antislanding | Disokong |
Pemantauan Arus Kebocoran | Disokong |
Pemantauan Impedans Penebat | Disokong |
Data Umum |
|
Dimensi (W*H*T mm) | W350*H580*T230 mm |
Timbang | 25kg |
Julat Suhu Operasi | -25℃~60℃ |
Pengambilan Sendiri Pada Waktu Malam | <10W |
Struktur Topologi | Reka Bentuk Tanpa Transformer |
Kaedah Penyejukan | Penyejukan Semulajadi |
Kelas Perlindungan | IP65 |
Kelembapan Relatif | 0-95% Tiada Kondensasi |
Ketinggian | 2000m |
Jenis Sambungan DC | MC4 |
Jenis Sambungan AC | Penyambung |
Mod Paparan | LCD |
Antaramuka Komunikasi | RS485/BOLEH/USB |
Antara Muka Pemantauan | WIFI |
Waranti: | 5 Tahun |
Pensijilan | VDE 0126-1-1: 2013 + VFR: 2019 / VDE-AR-N 4105: 2018-11 + Pembetulan 1:2020-1 |
EN IEC 61000-6-1: 2019 / EN IEC 61000-6-3: 2021 / EN 62109-1:2010 / EN 62109-2:2011 / EN 50549-1: 2019(1) |
IEC 62321-3-1:2013 / IEC 62321-4:2013+A1:2017 / IEC 62321-5: 2013 / IEC 62321-7-1:2015 / IEC 62321-7-2:2017 / IEC 62321-7-2:2017 / IEC 62321-7-1:2015 / IEC 62321-7-2:2017 / IEC 6215 / IEC 62321-8:2017 / IEC 62116 |
Syor Kejuruteraan ENA G98 Isu 1 Pindaan 6 / September 2021 / ENA Syor Kejuruteraan G99 Isu 1 Pindaan 8, 01 / September 2021 |
RD 647 / 2020 / RD 413 / 2014 / RD 1699 / 2011 / UTE C15-712-1 (JULAI 2013) / DOC-030221-GAP / (EC) No. 1907; 2006 / UNE-EN SO / IEC 17065 |
DARI VDEV 0124-100(VDE V0124-10):2020-06 / CEI-021:2019 CEI 0-21:2022-03+V1:2022-11 / NRS-097 / EMC(IEC61000-2-2)&CISPRP |